Circuit protection
Glow-wire 960 °C and UL 94 rated at a 0.8 mm wall, for MCB, RCCB, MCCB and contactor parts.
Engineering compounds since 1999
Tell us what it has to survive: heat, current, coolant, impact or a 960 °C glow-wire. We name one compound, prove it on your press and hold it lot after lot.

Air intake manifold in glass-fibre reinforced polyamide, one of six under-hood parts in series supply.
Eight needs bring most engineers, moulders and buyers to us. Choose yours to see what we do about it, and the evidence behind it.
Same tool, same process, compounded in India.
See the solutionRated at 0.8 mm, where the data sheet stops.
See the solution30–50% lighter in glass-reinforced polyamide.
See the solutionHydrolysis-resistant PA66 and mPPE, in series in end tanks.
See the solutionDeclared content, the same release standard.
See the solutionΔE ≤ 0.5, and a certificate with every lot.
See the solutionThe qualification pack, PPAP and audits.
See the solutionFrom brief to trial lot in five steps.
See the solutionSearch 97 standard grades by code, polymer, property or part. Or type the grade you run today.
Parts that carry current, hold pressure and sit next to heat, in the two markets where a material failure costs the most.
Glow-wire 960 °C and UL 94 rated at a 0.8 mm wall, for MCB, RCCB, MCCB and contactor parts.

Six under-hood parts in series today, supplied under IATF 16949 with PPAP and IMDS data.
Every recommendation is a grade that is in series supply or ready to specify, matched to what that part has to survive.
Glow-wire 960 °C, flat after riveting, in the grey or white of your range.
Operated thousands of times, so it needs toughness and snap strength.
The hottest, most stressed polymer in the device. It needs heat resistance, UL 94 V-0 and stiffness.
Latches and levers that must release at the right force for the life of the breaker.
Live conductors under screw torque. The material needs tracking resistance and a 960 °C glow-wire rating.
Snap-fit parts, busbar supports and accessories that sit near live parts.
What goes wrong: flange warpage that opens the gasket joint; sink marks on the visible cover.
What goes wrong: latch and hinge fracture after hundreds of filter changes.
What goes wrong: cracking at the crimp foot or hose spigot after coolant ageing.
What goes wrong: brittle straps from under-conditioned material; pawl failure from short shots.
What goes wrong: blade-root fatigue cracking; imbalance and noise from warpage. The fan sits behind the front panel in this photo.
What goes wrong: weld-seam leaks or low burst pressure; flange cracking after thermal cycling.
What stands behind a recommendation from Calco.
You get one named grade and the alternative, never a list to choose from. If a lower-cost grade will pass your test, or ours will not, we tell you before the trial.
Part function, load case, environment, fire and electrical requirements, target cost.
A grade from the six families, or one tailored to your specification.
Trial lots from 25 kg, mould trials at your site, test reports against your specification.
Material approval and PPAP documentation, with batch release controls.
Scheduled or just-in-time deliveries, a certificate with every lot and ongoing technical support.
Every family shares one method: formulate, mould, test, release.
Polyamide 6 and 66
The engineering workhorse: tough, wear- and heat-resistant, unfilled to 60% glass fibre.
31 gradesPBT and PBT alloys
Dimensional precision and electrical performance with low moisture uptake.
20 gradesPolypropylene
Chemical resistance, low density and cost efficiency, glass, talc and mineral reinforced.
13 gradesPolycarbonate and alloys
Impact strength down to low temperatures with high heat resistance.
10 gradesModified PPE
Very low water absorption and outstanding hydrolysis and glycol resistance.
See the familyRecycled-content polyamide
Polyamide engineering from polymer recovered from yarn and tyre-cord waste.
8 gradesSolution brand: fire safety
Flame-retardant compounds under UL file E541646, built for 960 °C glow-wire.
7 gradesSolution brand: recycled content
Declared post-industrial recycled content, released to the same specification as virgin grades.
7 gradesEvery grade is moulded into test specimens and characterised in our NABL-accredited laboratory. Reference granulate and colour standards are retained, so the thousandth lot behaves like the first.
Quality and laboratory10% of the polymer we use is post-industrial recycled material. No process water leaves our plant, solar power is generated on site, and we aim to be carbon neutral by 2030.
SustainabilityQualify Calco with the evidence your quality team asks for: test data at your wall thickness, PPAP, UL and a full qualification pack.
Qualify CalcoBring 1,000+ engineering grades to your market, backed by our laboratory, our application engineers and export-ready supply.
Become a partnerAn application engineer replies with a recommended grade or a development plan.
contact@calco.in
+91 70820 05247